800-749-3677
 
Download PDF of this page  Print this page
View PDF

CTHT-17100 Series Current Transformer

Current transformers (CT’s), like traditional transformers, convert voltages and currents based on their turns ratio. The most important relationship for CT's is primary amp-turns equaling secondary amp-turns (Ip Np = Is Ns). This series of CT's uses a customer supplied single turn primary through the center to carry the large circuit current. An appropriate turns ratio and terminating resistor are selected to supply a voltage, Vs = Is Rb, for the monitoring circuit.

The CT benefits include safety agency isolation and isolation required by circuit needs. High current is sometimes difficult to monitor directly. It is easy using an appropriate CT. The CTHT series of current transformers are usable up to 90 Amps peak.

Features:
  • Low Cost Encapsulated Transformer
  • Designed for Use Over a Wide Frequency Range
  • Sensitivity Can Be Set to Match Your Specific Requirements
  • Can be Provided With Installed Primary for Easy PCB Installation
  • Other Configurations Available Upon Request - Contact Precision

 
 * For standard product: Please select the quantity for each item you wish to order or receive a quote and click the 'Add To Quote' button below.

* For custom product: Please click 'Custom' button below. You will be directed to a page where you can add custom product information and attach prints.
 
Model
Turn
Inductance mHy (Min)
DCR Ohms (Max)
Rb** Ohms
Add Qty.
CTHT-17100-0500  50
5
0.24
50
CTHT-17100-1000  100
20
0.93
100
CTHT-17100-1500  150
45
2.2
150
CTHT-17100-2000  200
80
3.7
200
CTHT-17100-3000  300
180
8.7
300
CTHT-17100-4000  400
320
14.3
400
CTHT-17100-5000  500
500
23
500
CTHT-17100-7500  750
1150
57
750
Displaying 1 to 8 (of 8 products) Result Pages:  1 
Custom  

** Burden resistance value yielding, 1 Volt per amp output with a single primary turn (Np = 1)

CTHT-17100-1000, -2000 and -5000 are preferred products. 

** Burden resistance value yielding 1 volt per amp output with a single primary turn (Np=1).

Mechanical Characteristics:

CTHT Mechanical Drawing

Electrical Characteristics:

 
To match your monitoring circuitry to a specific CT, you need to know the CT characteristics in relationship to input current, turn ratio, and frequency range. The Rb referenced in the curves below is defined as Rb = 1 Volt/Is, the value which will yield one volt per amp output, where Is=(Np/Ns) Ip. To assist with choosing Rb, see graphs below. Lower or higher Rb values can be used for your specific requirements. Contact a Precision engineer for assistance (See buttons below).
 
Note: All results shown assume a square waveform for the current, where Ton=0.5T. Other wave forms are supported to slightly higher peak currents.
 
 