Features:
- Low cost encapsulated transformer
- Designed for use at 20 kHz and above
- Sensitivity can be set at 1 Volt per Amp
or other desired value
- Can be provided with installed primary
for easy PCB installation
- Other configurations available upon
request - Contact Precision
| Precision Part Number |
Number of Turns |
Inductance Min. in mHy |
DC Resistance Max. in ohms |
Sensed Current Max. in Amps |
**Terminating Resistor in Ohms |
| CTHT-17100-0500 |
50 |
5 |
0.5 |
10 |
50 |
| CTHT-17100-1000 |
100 |
20 |
1.4 |
24 |
100 |
| CTHT-17100-1500 |
150 |
45 |
3 |
30 |
150 |
| CTHT-17100-2000 |
200 |
80 |
4.5 |
35 |
200 |
| CTHT-17100-3000 |
300 |
180 |
11 |
40 |
300 |
| CTHT-17100-4000 |
400 |
320 |
18 |
50 |
400 |
| CTHT-17100-5000 |
500 |
500 |
30 |
40 |
500 |
| CTHT-17100-7500 |
750 |
1150 |
50 |
30 |
750 |
** Terminating resistor value to deliver 1 volt
per amp with single turn primary.
Notes:
- Test Circuit Leads "2" and "A" are in phase per orientation
shown above.
- Exact Case configuration may differ slightly from Illustration.
|