LDT-1320 Series Switchmode Power Inductors

Features:
  • High saturation materials, ideal for applications requiring both high-current rating and small size
  • Used in switching regulators, power supplies, RFI suppression and filters
  • Finished with UL-VW-1 rated sleeve
  • Open Magnetic circuit construction

 
 * For standard product: Please select the quantity for each item you wish to order or receive a quote and click the 'Add To Quote' button below.

* For custom product: Please click 'Custom' button below. You will be directed to a page where you can add custom product information and attach prints.
 
Model
Inductance
L0 (μH)

DCR mΩ
(MAX)
@ 25 ± 5°C

I-sat Amps
90% L0+

Test
Frequency

Add Qty.
LDT-1320-102  1000
1200
0.80
1KHz /1V
LDT-1320-821  820
1010
0.90
100KHz /1V
LDT-1320-561  560
640
1.00
100KHz /1V
LDT-1320-681  680
710
1.00
100KHz /1V
LDT-1320-471  470
560
1.20
100KHz /1V
LDT-1320-391  390
510
1.30
100KHz /1V
LDT-1320-271  270
340
1.50
100KHz /1V
LDT-1320-331  330
450
1.50
100KHz /1V
LDT-1320-221  220
250
1.80
100KHz /1V
LDT-1320-181  180
190
2.00
100KHz /1V
LDT-1320-151  150
170
2.10
100KHz /1V
LDT-1320-121  120
140
2.30
100KHz /1V
LDT-1320-101  100
120
2.50
100KHz /1V
LDT-1320-820  82
95
2.60
100KHz /1V
LDT-1320-680  68
90
3.00
100KHz /1V
LDT-1320-560  56
80
3.20
100KHz /1V
LDT-1320-470  47
70
3.60
100KHz /1V
LDT-1320-390  39
70
3.80
100KHz /1V
LDT-1320-330  33
70
4.00
100KHz /1V
LDT-1320-270  27
50
4.50
100KHz /1V
Displaying 1 to 20 (of 35 products) Result Pages:  1  2  [Next >>] 
Custom Add to Quote  

 

Mechanical

 

LD Mechical Drawing

 

U of M A
(Max)
B
(Max)
C
(Min)
D
(Max)
E F
Typ
mm 13.0 20.0 3.5 3.0 6.0 ± 0.5 Φ0.80
in 0.51 0.78 0.13 0.11 0.23 ± 0.019 Φ0.031

 

Packaging

Typical Construction

Pocket Image Bag Size:
150*200*0.08m/m

Quantity:
100pcs/bag
Package Inner box Innerbox Size:
160*140*90m/m

Quantity:
5bag/innerbox
Package Carton Outbox Size:
335*295*200m/m

Quantity:
8 innerbox/outbox

Storage

  1. Temperature and humidity conditions: Less than 25±5°C and 70% RH.
  2. Recommended products should be used within 6 months from the time of delivery.
  3. The packaging material should be kept where no chlorine or sulfur exists in the air.

Transportation

  1. Products should be handled with care to avoid damage or contamination from perspiration and skin oils.